FLOODED DEEP CYCLE BATTERY |
S6 250 |
|
|
| Series | FLA SERIES 4000 | Warranty | 3 Years |
|---|---|---|---|
| Volts | 6 | Design | 901 |
| Cells | 3 | Plates/Cell | 19 |
| Terminal Type | DT | ||
| Included Hardware | Stainless Steel K-Lock Nut | ||
| Size & Thread | 5/16"-18 | ||
| Charge | Discharge | |
|---|---|
| Charge Voltage Range | 2.45-2.5 V/cell @ 25°C (77°F) |
| Float Voltage Range | 2.25 V/cell @ 25°C (77°F) |
| Recommended Charge Current | 35 A |
| Maximum Charge Current | 55 A |
| Self-Discharge Rate | 5%-10% per month at 25°C (77°F) |
| Capacity | |
|---|---|
| Cold Crank Amps (CCA) 0°F / -18°C | 799 |
| Marine Crank Amps (MCA) 32°F / 0°C | 998 |
| Reserve Capacity (RC @ 25A) | 544 Minutes |
| Reserve Capacity (RC @ 75A) | 143 Minutes |
| Capacity Affect by Temperature | 40°C (104°F) |
25°C (77°F) |
0°C (32°F) |
-15°C (5°F) |
|---|---|---|---|---|
| 105% | 100% | 75% | 50% |
| Hour Rate | Capacity / AMP Hour | Current / AMPs |
|---|---|---|
| @ 100 Hour Rate | 360 AH | 3.6 A |
| @ 72 Hour Rate | 354 AH | 4.92 A |
| @ 50 Hour Rate | 334 AH | 6.69 A |
| @ 20 Hour Rate | 281 AH | 14.05 A |
| @ 15 Hour Rate | 267 AH | 17.8 A |
| @ 10 Hour Rate | 247 AH | 24.73 A |
| @ 8 Hour Rate | 242 AH | 30.21 A |
| @ 5 Hour Rate | 222 AH | 44.4 A |
| @ 1 Hour Rate | 112 AH | 112.4 A |
| Specifications | |||
|---|---|---|---|
| Weight | 40 kg | 88 lbs | |
| Length | 298 mm | 11.75" | |
| Width | 181 mm | 7.13" | |
| Height Incl. Term. | 286 mm | 11.25" | |
| Product measurements & weights are calculated based on sample data. Individual specifications are subject to vary due to the manufacturing process & battery components. | |||
| Electrolyte Reserve | 44 mm | 1.75" | |
|---|---|---|---|
| Container | Polypropylene | ||
| Cover | Polypropylene | ||
|
|||
Cycle Life vs. Depth of Discharge
Voltage vs. Depth of Discharge
Detailed Illustration