Skip to main content

VRLA AGM DEEP CYCLE BATTERY

S12-110AGM FT

Series AGM-S Warranty See Warranty Terms
Volts 12 Design SPEC
Cells 6
Terminal Type F14(M8)
Included Hardware M8 stainless bolts & washers
Size & Thread M8
Charge
Charge Voltage Range 14.7V @ 25°C (77°F)
Float Voltage Range 13.8V @ 25°C (77°F)
Recommended Charge Current 22 A
Maximum Charge Current 30 A
Self-Discharge Rate Less than 2% per month at 25°C (77°F)
Internal Resistance 6.0 
Capacity
Capacity Affect by Temperature 40°C
(104°F)
25°C
(77°F)
0°C
(32°F)
-15°C
(5°F)
102% 100% 85% 65%
Hour Rate Capacity / AMP Hour Current / AMPs
@ 20 Hour Rate 110 AH 5.5 A
@ 10 Hour Rate 100 AH 10.0 A
@ 5 Hour Rate 85 AH 17.0 A
Cut Off Voltage Constant Current Discharge
1.75 VPC 1 hr2 hr3 hr4 hr5 hr8 hr10 hr
55.032.925.820.417.412.210.1
Specifications
Weight 31 kg 68 lbs
Length 394 mm 15.5"
Width 110 mm 4.33"
Height Incl. Term. 286 mm 11.25"
Product measurements & weights are calculated based on sample data. Individual specifications are subject to vary due to the manufacturing process & battery components.
Container ABS
Cover ABS
Handles Rope / Plastic Handle
  • Plastics are UL94 HB (UL94 V0 available)
  • Valve regulated design with integral flame arrestor
  • Non-hazardous, Non-spillable

Cycle Life vs. Depth of Discharge

Capacity vs. Temperature

Detailed Illustration

Rev.#2 | August 2024