FLOODED DEEP CYCLE BATTERY |
8 HHG 21P |
|
|
| Series | FLA SERIES 4000 | Warranty | 3 Years |
|---|---|---|---|
| Volts | 8 | Design | SLI |
| Cells | 4 | Plates/Cell | 21 |
| Terminal Type | Flag L | ||
| Included Hardware | S/S Hex Cap Screw, Nut, Lock & Flat Washer | ||
| Size & Thread | 5/16"-18 | ||
| Charge | Discharge | |
|---|---|
| Charge Voltage Range | 2.45-2.5 V/cell @ 25°C (77°F) |
| Float Voltage Range | 2.25 V/cell @ 25°C (77°F) |
| Self-Discharge Rate | 5%-10% per month at 25°C (77°F) |
| Capacity | |
|---|---|
| Cold Crank Amps (CCA) 0°F / -18°C | 1033 |
| Marine Crank Amps (MCA) 32°F / 0°C | 1291 |
| Reserve Capacity (RC @ 25A) | 552 Minutes |
| Reserve Capacity (RC @ 75A) | 184 Minutes |
| Capacity Affect by Temperature | 40°C (104°F) |
25°C (77°F) |
0°C (32°F) |
-15°C (5°F) |
|---|---|---|---|---|
| 105% | 100% | 75% | 50% |
| Hour Rate | Capacity / AMP Hour | Current / AMPs |
|---|---|---|
| @ 100 Hour Rate | 306 AH | 3.06 A |
| @ 72 Hour Rate | 290 AH | 4.03 A |
| @ 50 Hour Rate | 274 AH | 5.47 A |
| @ 20 Hour Rate | 230 AH | 11.5 A |
| @ 15 Hour Rate | 219 AH | 14.57 A |
| @ 10 Hour Rate | 202 AH | 20.24 A |
| @ 8 Hour Rate | 198 AH | 24.73 A |
| @ 5 Hour Rate | 182 AH | 36.34 A |
| @ 1 Hour Rate | 92 AH | 92 A |
| Specifications | |||
|---|---|---|---|
| Weight | 53.5 kg | 118 lbs | |
| Length | 540 mm | 21.25" | |
| Width | 187 mm | 7.38" | |
| Height Incl. Term. | 283 mm | 11.13" | |
| Product measurements & weights are calculated based on sample data. Individual specifications are subject to vary due to the manufacturing process & battery components. | |||
| Electrolyte Reserve | 70 mm | 2.75" | |
|---|---|---|---|
| Container (Inner) | Polypropylene | ||
| Cover (Inner) | Polypropylene - heat sealed to inner container | ||
| Container (Outer) | High Density Polyethylene | ||
| Cover (Outer) | High Density Polyethylene snap fit to outer container | ||
| Handles | Rope | ||
|
|||
Voltage vs. Depth of Discharge