Skip to main content

FLOODED DEEP CYCLE BATTERY

12 FS 24

Series FS Warranty 1 Year
Volts 12 Design Grp 24
Cells 6
Terminal Type DT
Included Hardware Stainless Steel K-Lock Nut
Size & Thread 5/16"-18
Charge
Charge Voltage Range 14.7-15 V/cell @ 25°C (77°F)
Self-Discharge Rate 5%-10% per month at 25°C (77°F)
Capacity
Cold Crank Amps (CCA) 0°F / -18°C 550
Marine Crank Amps (MCA) 32°F / 0°C 690
Reserve Capacity (RC @ 25A) 150 Minutes
Reserve Capacity (RC @ 75A) 43 Minutes
Capacity Affect by Temperature 40°C
(104°F)
25°C
(77°F)
0°C
(32°F)
-15°C
(5°F)
105% 100% 75% 50%
Hour Rate Capacity / AMP Hour Current / AMPs
@ 100 Hour Rate 106 AH 1.06 A
@ 20 Hour Rate 85 AH 4.25 A
@ 15 Hour Rate 80 AH 5.33 A
@ 10 Hour Rate 72 AH 7.23 A
@ 8 Hour Rate 71 AH 8.82 A
@ 5 Hour Rate 69 AH 13.8 A
@ 1 Hour Rate 31 AH 30.6 A

Ampere hour capacity ratings based on specific gravity of 1.280 at 27°C (80°F).
Reduce capacities 5% for specific gravity of 1.265 and 10% for 1.250.

Specifications
Weight 21.5 kg 47.5 lbs
Length 279 mm 11"
Width 171 mm 6.75"
Height Incl. Term. 238 mm 9.38"
Product measurements & weights are calculated based on sample data. Individual specifications are subject to vary due to the manufacturing process & battery components.
Container ABS
Cover ABS
Handles Plastic Strap
  • Plastics are UL94 HB (UL94-V2 available)
  • Plastics are impact copolymer rated to ASTM D256, D5420
  • Vented design with integral flame arrestor vent caps

Cycle Life vs. Depth of Discharge

Voltage vs. Depth of Discharge

Detailed Illustration

Rev.#2 | August 2024